You are here

Energy Light

combines low emissivity and solar control features

-

Energy Light has one remarkable advantage : its magnetron coating can be used for both annealed and toughened glass applications, while offering similar aesthetics and performances. Processors have only one single product to stock.

This product is available in France, Belgium, The Netherlands and Germany.

Energy Light is also available on Clearvision, AGC Glass Europe's low-iron glass.

Structure % % % % % W/(M².K)
Energy Light τv ρv αe g SC Ug-Value
4| - 14 Ar 90% - 4 - 14 Ar 90% - |4 60 29 21 39 0.45 0.6
4| - 15 Ar 90% - 4 65 26 19 43 0.49 1.0
4| - 16 Ar 90% - 4 - 16 Ar 90% - |4 57 30 23 37 0.42 0.5
6| - 15 Ar 90% - 44.2 64 26 25 42 0.48 1.0

Abbreviations:
LT: Light Transmission; LR: Light Reflection; UV: Ultraviolet transmission; EA: Energy Absorption; SF: Solar Factor.

Symbols:

  • The | symbol indicates the position of the solar-control coating.
  • The ¦ symbol indicates the position of a low-emissivity coating (iplus Top 1.1).
  • The ! Symbol indicates the position of a low-emissivity coating (Planibel G)

Tolerances:
The data are calculated using spectral measurements that are conform to standards EN 410 (1998).
The tolerance of published data with respect to photometric properties is +/- 3 points.
The U-value (formerly k-value) is calculated according to standard EN 673.
The emissivity measurement complies with standards EN 673 (Annex A) and EN 12898. The U-value tolerance is +/- 0.1W/(m²K).
This information is no evaluation of the risk of glass breakage due to thermal stress.